Assessment of various unit control architectures alan fox. Woodward 505 governor steam turbine generator application. The first part of this manual is written to give users an idea of the 505e digital controls capabilities, and how to apply them to a system. Maintenance introduction this chapter provides information for the dial speed setting system. Woodward pg 500 governor 14 woodward hydraulic gateshaft type turbine water wheel governor manual 106 woodward manual for adjustable blade control for gate shaft governors. Overview of woodward governor 505 instrumentation tools. General information description the 99059907 series of the woodward 2301a controls load sharing and speed of generators driven by diesel or gasoline engines, or steam or gas turbines. Woodward governor company reserves the right to update any portion of this publication at any time.
Overview of woodward governor 505 governor is a device which senses the speed of an engine or turbine and controls the fuel or steam to the engine or turbine to maintain the speed at a desired level to meet changes in load or horse power op required. English versions are 9907165, 9907166, and 9907167. Substitution of components may impair suitability for class i, division 2. Send me the part number of the 505 and i will help you with your problem. Pg governor dial type speed setting manual 36614 2 woodward chapter 2. On a woodward governor, the shutdown rods that act on the. The main pg manual for the particular governor provides disassembly procedures for the basic governor. Welcome to the woodward governor company unofficial. Installation and operation manual 505e digital governor for extraction steam turbines volume 1 manual 85018v1.
A governor is a device which controls the energy source to a prime mover to control its power basic governors sense speed and load of a prime mover and adjust the energy source to maintain the desired level governors can control multiple parameters and multiple prime movers. This workstation allows an operator to remotely view operating inputs, vary control setpoints, and issue run mode commands. Woodward 505 governor controlling operation askpowerplant. To navigate through the ribbon, use standard browser navigation keys.
Woodward 505 turbine governor panel manual download pdf. Magnetic speed pickups be prepared to make an emergency shutdown when starting the engine, turbine, or other type of prime mover, to protect against runaway or overspeed with possible personal injury, loss of life, or property damage. Description the woodward tg10 is a mechanicalhydraulic speed droop governor for. Manual 36692 provides disassembly instructions for the power cylinder. General information introduction this manual provides general information, installation, operation and adjustments, principles of operation, troubleshooting, and replaceable parts for the woodward tg10 governor. Pdf installation and operation manual 505e digital. Woodward 505 governor is a microprocessor based electronic controller having lot of inbuilt facilities. This governor was professionally decommissioned and removed from service due to plant conversion and upgrade. General information introduction this manual 85018 describes the woodward 505e digital governor for steam turbines with controlled extraction andor admission pressure control. Woodward 505 installation and operation manual pdf download. This controller has algorithms and logic to start, stop, control, and protect. Manual 85018v1 505e digital governor woodward 1 chapter 1. Governor systems are required to always meet or exceed the performance and reliability requirements of ieee 125.
Optionally, users can increase the number of input and output signals tofrom the. General information introduction this manual describes the woodward proact digital speed control and proact 75 degree electric powered actuators, models i and ii. In speed control the speed set point is given in the woodward keypad but in remote speed set point it is not clear and i. The 505 is designed to operate a variety of steam turbines and applications. Optionally, this service tool can also be used to trend unit parameters, to compare differences in configuration files, and to verify if control settings have been changed. Woodward 505 installation and operation manual pdf. The woodward control assistant software program is a computerbased service tool that can be used with the 505e control to upload, save, and download controller configurations. Slideshare uses cookies to improve functionality and performance, and to. Woodward 505 manual printed circuit board valve scribd. Introduction of woodward 505e governor today we discussed about the turbine governring system and its working, features and its operation and also its programming.
A governor is a device which controls the energy source to a prime mover to control its power basic governors sense speed and load of a prime mover and adjust the energy source to maintain the desired level governors can control multiple parameters and multiple prime movers basic control loop a basic prime mover. Optionally, users can increase the number of input and output signals tofrom the 505 by connecting pre. From your description, it sounds like the 505 offline dynamics need to be tuned to prevent the over frequency shutdown. The speed reference for this type of governor was a combination of a remote reference 94 20 m a from a process controller and a manual potentiometer, with the. Our purpose built governor workshops are all iso 9001 certified and fully equipped with the highly trained and experienced personnel and specialized tools required to complete repairs and overhauls and comprehensive testing on the full range of woodward governors and actuators. Information provided by woodward governor company is believed to be correct and reliable. Woodward 8256016,woodward inc,epg rotary actuator, model 1724, 24vdc,winn marion companies. Product manual 04042 revision l, 220 original instructions tg and tg17 governors tg611 and tg61117 governors installation and operation manual. Manual 82510 magnetic pickups and proximity switches woodward 3 chapter 1. The solenoid is usually tripped automatically under any of the following conditions. Manual tools woodward governor thank you very much for reading manual tools woodward governor.
In woodward 505e governor is very sensitive governor in which lots of inbuilt. Woodward manual 26455 8 product spec technicalmanual applicationnote 3161 governor 03102 03101 3161 governor 03110 solid piston air pressure fuel limiter 03107 speed adj motor w manual speed adjust 03108 air pressure fuel limiter 03105 electric shutdown device. Manual 85017v2 505 digital governor woodward 39 chapter 3. Opview interface for 505505e controls manual 85015 2 woodward chapter 2. Woodward is the worlds largest independent designer and manufacturer of energy control solutions, including governors, actuators, and controls for industrial engines, turbines, and power equipment.
Manual 26839v2 505 digital governor for singlesplitrange actuators derivative, sometimes called preact or rate, is very difficult to draw an accurate analogy to, because the action takes place only when the process changes and is directly related to the speed at which the process changes. Send us your list of part numbers and quantities for a prompt quotation. Woodward technical product specifications and technical manuals are available in pdf. Jul 30, 2019 woodward 505 turbine governor panel manual. Maybe you have knowledge that, people have search numerous times for their favorite novels like this manual tools woodward governor, but end up in harmful downloads. The existing governor system has two critical dependencies. Depending on the part number of your 505 what you want to accomplish is very possible. The 505 and 505xt are woodwards line of standard offtheshelf controllers for operation and protection. Opview operator interface for woodward 505 and 505e. Woodward industrial turbomachinery control and protection.
Woodward 8256016,epg rotary actuator, model 1724, 24vdc. Manual 26839v1 505 digital governor for singlesplitrange actuators woodward 1 contents warnings and notices. This manual includes application specific notes and 505e specific service mode information. View and download woodward 505 installation and operation manual online. The woodward 505 digital governor turbine control is a controller purpose built to provide exemplary operation and protection of industrial steam turbines. Designed for steam turbine control, the 505 control includes four pid controllers speed, cascade, aux1, aux2, multiple startup.
Description the opview touch screen workstation functions as an annunciator and operator control panel for woodwards 505 and 505e digital control. Goltens is a specialist in governor service and repairs. In 1870 our founder, amos woodward, invented a responsive, noncompensating governor for water wheels. Sunny enterprises woodward governor helpline 03124225402. Woodward 505 manual free ebook download as pdf file. Manual 26839v2 505 digital governor for singlesplitrange actuators derivative, sometimes called preact or rate, is very difficult to draw an accurate analogy to, because the action takes place only when the process changes and is directly related to the speed at. Manual 26361v1 505de digital governor woodward iii illustrations and.
Unpluggable terminal blocks allow for easy system installation, troubleshooting, and replacement. Read this entire manual and all other publications pertaining to the work. Since then, weve been leveraging those basic mechanical governor principles into the worlds best mechanical, hydraulic, and electronic governors for engines and steam turbines. Proact digital speed control system for models i and ii. The 505de is built on woodwards fieldproven micronet plus platform.
602 1358 1158 390 1515 1342 278 422 37 717 902 400 1166 615 1037 922 1015 1128 1306 693 335 954 874 775 350 1221 440 1195 986 936 109 859 1486 3 1318 718 783 1368 181 1195 1172 638 645 1212 970 940 683 725